Servo drives hero Panasonic Industry

Motion Controller GM1

Combines programmable logic and motion control in one device for high productivity – efficient and economic.
Motion Controller GM1

Motion Controller GM1 for complex motion control applications

With the space-saving Motion Controller from Panasonic Industry you can master your challenges with your multi-axes machines: The GM1 offers control of up to 32 axes (16 physical and 16 virtual axes), standardized communication via EtherCAT, easy network integration via EtherNet/IP, and sophisticated programming with CODESYS.

All these features make the Motion Controller the ideal choice for use in machines with challenging motion profiles such as rotary knives, path interpolation or synchronization and coupling of axes.

The GM1 is a combination of several units (a positioning unit, a network unit, an I/O unit, and a high-speed counter unit) which in conventional solutions have to be installed separately.

Overview of the most important functions and features

Configuration software with

  • User assistance for choosing the right function blocks
  • Smooth editing of cam curves
  • Simulation and debug function

 

Synchronous control

  • Complex multi-axis systems like systems with 2- and 3-axis interpolation

 

High-speed response

  • For fast data exchange and networking

 

Programming with CODESYS

  • Standard programming languages according to international standard IEC 61131

 

Motion control Ethernet RS232C Selectable network
  • Real axes: 32 (EtherCAT type)
  • Real axes: 16 (RTEX type)
  • Equipped with 2 ports
  • EtherNet/IP (1 port)
  • Modbus-TCP
  • General-purpose communication
  • FTP server / client
  • OPC UA server
  • Modbus-RTU
  • Program-controlled communication
  • EtherCAT
  • RTEX
General-purpose I/O High-speed counter input High-speed response PWM output
  • 16 inputs and 16 outputs
  • NPN/PNP transistor outputs
  • 64 I/O per expansion unit (up to 15 units possible)
  • 2 channels
  • 4-fold evaluation by 16MHz
    • Shortest command cycle: 0.5ms
    • 4 channels
    • Up to 100 kHz

    Applications

    The GM1 is specially designed for motion control solutions, where high precision like interpolation control and a sensitive response are needed. Therefore, the space-saving Motion Controller offers high-speed and high accuracy for applications like printing, packaging, press-fitting, or molding. Compared to conventional PLCs, the GM1 is ideally suited for motion applications like a rotary knife, flying shear, labeling, palletizer, crank, cam synchronization, or print mark evaluation (position control).

    Icon Robots 2
    Robots & handling systems
    Icon machine tools
    Machine tools
    Printing machines
    Printing machines
    Automated machinery
    Automated machinery
    Icon Packaging machinery
    Packaging machinery
    Icon Conveyors 
    Conveyors
    Icon Semiconductor production equipment
    Semiconductor production equipment

    Configuration software - GM Programmer

    GM Programmer is the associated software for setting the GM1 controller, editing, and downloading programs. It complies with the IEC 61131-3 standard.

    Users can choose between 6 different programming editors to configure their system. Settings can be tested before implementation with the offline simulation function.

    6 programming languages

    Servo Drives GM1 6 programming languages Panasonic Industry
    • LD (Ladder Diagram)
    • FBD (Function Block Diagram)
    • ST (Structured Text) 
    • SFC (Sequential Function Chart)
    • CFC (Continuous Function Chart)
    • IL (Instruction List)

    Easy programming with the help of the pre-installed standard library with function blocks for motion control. When you select a function block, the “Function Block Guidance” feature shows details about the function block parameters.

    Debugging is made easier by offline simulation and features such as motor tracing, timing adjustment and other functions. This helps to reduce the time and effort needed for designing the system.

    The intuitive graphical user interface allows you to configure the cam curves easily.

    Controller

    Servo Drives Motion Controller GM1 Panasonic Industry
    Number of axes Network Number of I/O High-speed counter Rated voltage Output specifications Part No.
    16 axes RTEX

    16 inputs

    16 outputs

    2 ch 24V DC Transistor output (NPN) AGM1CSRX16T
    32 axes EtherCAT

    16 inputs

    16 outputs

    2 ch 24V DC Transistor output (PNP) AGM1CSEC16P

    Input / output unit

    Servo Drives Motion Controller GM1 Digital Input / output unit Panasonic Industry
    Type Number of I/O Specifications Part No.
    DC input 64 inputs 24V DC, 32 inputs / 1 common AGM1X64D2
    Transistor output (PNP) 64 outputs Maximum load current: 0.3A (20.4 to 26.4V DC), 30mA (4.75V DC); 3.2A / common, 32 outputs / 1 common AGM1Y64P
    DC input / Transistor output (PNP)

    32 inputs

    32 outputs

    Input: 24V DC, 32 inputs / 1 common

    Output: Maximum load current: 0.3A (20.4 to 26.4V DC), 30mA (4.75V DC); 3.2A / common, 32 outputs / 1 common

    AGM1XY64D2P

    Analog input / output unit

    Servo Drives Motion Controller GM1 Analog input / output unit Panasonic Industry
    Product name Specifications Number of channels Part No.
    Analog input unit

    Conversion speed 50μs / ch

    Resolution 16bit (maximum)

    Accuracy max. ±0.2% F.S. (at +25°C)

    8 ch AGM1AD8
    Analog output unit

    Conversion speed 50μs / 4 ch

    Resolution 16 bit (maximum)

    Accuracy max. ±0.2% F.S. (at +25°C)

    4 ch AGM1DA4

     

    Pulse output unit

    Servo Drives Motion controller GM1Pulse output unit Panasonic Industry
    Output type Number of control axes Speed command Part No.
    Transistor 4 axes Max. 500kpps AGM1PG04T
    Line driver 4 axes Max. 4Mpps AGM1PG04L

     

    Accessories

    Product name Part No.
    Discrete-wire connector set AFP2801
    Flat cable connector set AFP2802
    Spring force plug set AFP2808
    Power cable AFPG805

     

    Downloads

    Name File Type Size Date Language
    PDF Bundle solution for motion application, Short overview 2023: Servo drives - Motion controller PLC - HMI - Communication, 4256euen Catalog, Shortform 1.9 MB 05.04.2023 English
    PDF Collaboration Catalog – Network, Linear and Direct Drive Motor Control System 2023-02 Catalog 18.5 MB 22.02.2023 English
    PDF Controlador de movimiento GM1, flyer, 4254eues Flyer 2.1 MB 20.02.2024 Spanish
    PDF Controlador de movimiento Serie GM1, 4255eues Catalog 5.8 MB 01.09.2022 Spanish
    PDF Contrôleur de mouvements multiaxes Série GM1 , 4255eufr Catalog 2.1 MB 24.05.2022 French
    ZIP GM Programmer V1.4.1.0: Programming software for motion controller GM1. Works with Windows 10/11. Software 1.1 GB 08.11.2023 English
    PDF GM1 Controller EtherCAT User’s Manual (Operation), WUME-GM1ETCOP-06 Manual 44.1 MB 10.11.2023 English
    PDF GM1 Controller EtherCAT User’s Manual (Setup), WUME-GM1ETCSU-03 Manual 5.2 MB 10.11.2023 English
    PDF GM1 Controller RTEX User’s Manual (Operation), WUME-GM1RTXOP-06 Manual 41.8 MB 10.11.2023 English
    PDF GM1 Controller RTEX User’s Manual (Setup), WUME-GM1RTXSU-05 Manual 4 MB 10.11.2023 English
    ZIP GM1 Motion Controller EtherCAT type, EDS file Software 2 KB 24.11.2021 English
    ZIP GM1 Motion Controller RTEX type, EDS file Software 2 KB 24.11.2021 English
    ZIP GM1 Motion Controller, Firmware Version-up Ver.1.4.0.1. Software 74.8 MB 17.04.2024 English
    PDF GM1 Motion Controller, flyer, 4254euen Flyer 2.2 MB 20.02.2024 English
    PDF GM1 Series Reference Manual (Analog I/O Unit Edition), WUME-GM1AIO-04 Manual 1.6 MB 10.11.2023 English
    PDF GM1 Series Reference Manual (Hardware), WUME-GM1H-07 Manual 4.1 MB 10.11.2023 English
    PDF GM1 Series Reference Manual (Instruction Edition), WUME-GM1PGR-06 Manual 19.1 MB 10.11.2023 English
    PDF GM1 Series Reference Manual (Pulse Output Unit), WUME-GM1PG-04 Manual 5.9 MB 27.09.2023 English
    ZIP GM1 series, CAD data, step CAD 2.3 MB 28.06.2022 English
    PDF Les essentiels - Produits d’automatisme, 6215eufr Catalog, Shortform 5.5 MB 16.06.2023 French
    PDF Motion Controller GM1 Serie, Katalog, 4255eude Catalog 2.1 MB 24.05.2022 Deutsch
    PDF Motion Controller GM1 Series, catalog, 4255euen Catalog 1.9 MB 01.09.2022 English
    PDF Top seller - Automation products, 6215euen Catalog, Shortform 15.7 MB 04.05.2023 English
    PDF Übersicht Topseller Automatisierungstechnik, 6215eude Catalog, Shortform 15.6 MB 24.04.2023 German