Efficient, reliable and consistently awesome
Built to last, this robust drive operates effectively and reliably even with the most demanding applications and in the most challenging environments.
VLT® AutomationDrive takes full advantage of all that the new digital age has to offer to ensure it completely fulfills the requirements of your applications and optimizes your processes throughout the entire lifecycle.
Its cutting-edge thermal design and unique back-channel cooling make VLT® AutomationDrive one of the most compact and cost-efficient drives in the market. Intelligent maintenance and monitoring functions improve the productivity, performance, and uptime of your systems in the long term.
Supply voltages and power range
- 3 x 200-240 V...0.25-37 kW
- 3 x 380-500 V...0.37 kW – 1.1 MW
- 3 x 525-600 V...0.75-75 kW
- 3 x 525-690 V...1.1 kW – 1.4 MW
Low harmonic drive
- 3 x 380-480 V...132-450 kW
12-pulse drive
- 3 x 380-500 V...250 kW – 1 MW
- 3 x 525-690 V...250 kW – 1.4 MW
Features and benefits
Fits all motor technologies and fieldbus protocols: universally compatible
Commissioning and upgrades are easy due to plug-in technology
Back-channel cooling concept reduces energy costs, size of the cooling system, and extends drive lifetime
Automatic Motor Adaptation (AMA) for fast startup
Automatic Energy Optimization (AEO) for high system efficiency
Safe stop and Safe Torque Off ensure safe operation of the drive
Integrated Motion Controller (IMC) for automation made easy
Condition-based monitoring (CBM) is integrated to achieve maximum uptime in your operations
VLT® Motion Control Tool MCT 10 offers a customized commissioning experience
Explore MyDrive® Suite for free software tools and downloads
‘Ruggedized’ design reduces the potential negative effects of vibration
DrivePro® Life Cycle Services proactively improve uptime of your plant
VLT® FlexConcept improves efficiency while reducing complexity in your system
Videos about VLT® AutomationDrive FC 302
Documents
Type | Name | Language | Valid for | Updated | Download | File type |
---|---|---|---|---|---|---|
Case story | AIDA Cruise Ships | English | Multiple | 20 Jul, 2023 | 1.0 MB | |
Case story | AIDA Cruise Ships | Spanish | Spanish, Castilian | Multiple | 20 Jul, 2023 | 1.0 MB | |
Case story | Arla Food Ingredients Group | English | Multiple | 09 Jun, 2023 | 700.5 KB | |
Case story | Arla Food Ingredients Group | Danish | Danish | Multiple | 09 Jun, 2023 | 673.5 KB | |
Case story | Arla Lactose | English | Multiple | 09 Mar, 2023 | 5.5 MB | |
Case story | Arla Lactose | Chinese | Chinese (CN) | Multiple | 09 Mar, 2023 | 5.7 MB | |
Case story | Arla Lactose | Danish | Danish | Multiple | 09 Mar, 2023 | 5.5 MB | |
Case story | Arla Lactose | Polish | Polish | Multiple | 09 Mar, 2023 | 5.5 MB | |
Case story | Bimbo Group Bakery | English | Multiple | 22 Mar, 2023 | 581.5 KB | |
Case story | Birra Peroni | English | Multiple | 15 Mar, 2023 | 13.7 MB | |
Case story | Birra Peroni | French | French | Multiple | 15 Mar, 2023 | 13.7 MB | |
Case story | Birra Peroni | Italian | Italian | Multiple | 15 Mar, 2023 | 14.1 MB | |
Case story | Bogense Plast | Danish | Danish | Multiple | 03 May, 2023 | 1.1 MB | |
Case story | Borsodi Brewery | English | Multiple | 15 Mar, 2023 | 2.6 MB | |
Case story | Borsodi Brewery | Polish | Polish | Multiple | 15 Mar, 2023 | 2.7 MB | |
Case story | Buhler Group | English | Multiple | 09 Nov, 2021 | 2.7 MB | |
Case story | Chinese liquor | Chinese | Chinese (CN) | Multiple | 31 Jan, 2023 | 4.8 MB | |
Case story | Chinese Tobacco | English | Multiple | 19 Jul, 2023 | 1.1 MB | |
Case story | CocaCola Severna - Full case | English | Multiple | 08 Sep, 2022 | 4.2 MB | |
Case story | CocaCola Severna - Full case - French | French | Multiple | 01 Dec, 2022 | 4.3 MB | |
Case story | CocaCola Severna - Full case | Chinese | Chinese (CN) | Multiple | 31 May, 2023 | 4.3 MB | |
Case story | CocaCola Severna - Mobile case | English | Multiple | 08 Sep, 2022 | 1.9 MB | |
Case story | CocaCola Severna - Short case | English | Multiple | 08 Sep, 2022 | 2.2 MB | |
Case story | CT Offshore | English | Multiple | 15 Mar, 2023 | 7.9 MB | |
Case story | CT Offshore | Chinese | Chinese (CN) | Multiple | 15 Mar, 2023 | 8.0 MB | |
Case story | Danish Crown | Danish | Danish | Multiple | 20 Mar, 2023 | 5.5 MB | |
Case story | Danish Crown | English | English | Multiple | 20 Mar, 2023 | 5.5 MB | |
Case story | Drytech | English | English | Multiple | 20 Mar, 2023 | 2.3 MB | |
Case story | EFES Pilsen Turkey | English | English | Multiple | 15 Mar, 2023 | 1.8 MB | |
Application guide | Encoder-less Safety using DOLD Module | English | Multiple | 15 Apr, 2017 | 5.9 MB | |
Application guide | Encoder-less Safety using DOLD Module | German | Multiple | 08 Sep, 2017 | 6.1 MB | |
Case story | Ensus biorefinery | English | English | Multiple | 19 Jul, 2023 | 2.6 MB | |
Case story | Erdos Chemical Lime | English | English | Multiple | 14 Jul, 2023 | 1.7 MB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | German | Multiple | 07 Mar, 2023 | 427.7 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | English | Multiple | 07 Mar, 2023 | 357.2 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | Polish | Multiple | 07 Mar, 2023 | 391.8 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | Dutch, Flemish | Multiple | 07 Mar, 2023 | 396.5 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | Chinese (CN) | Multiple | 07 Mar, 2023 | 470.3 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | Danish | Multiple | 07 Mar, 2023 | 358.3 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | French | Multiple | 07 Mar, 2023 | 403.8 KB | |
Fact sheet | Fact Sheet - VLT® AutomationDrive FC 302 with integrated motion controller – for positioning and synchronization applications | Czech | Multiple | 07 Mar, 2023 | 393.9 KB | |
Fact sheet | Factsheet - Predictive/condition-based maintenance functions – for maximum availability of your application | English | Multiple | 24 Mar, 2023 | 2.4 MB | |
Fact sheet | Factsheet - Predictive/condition-based maintenance functions – for maximum availability of your application | Czech | Multiple | 27 Jul, 2023 | 1.5 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions | German | Multiple | 24 Mar, 2023 | 1.5 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions | French | Multiple | 24 Mar, 2023 | 1.5 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions – for maximum availability of your application | Dutch, Flemish | Multiple | 24 Mar, 2023 | 1.5 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions – for maximum availability of your application | Chinese (CN) | Multiple | 24 Mar, 2023 | 1.6 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions – for maximum availability of your application | Russian | Multiple | 24 Mar, 2023 | 1.5 MB | |
Fact sheet | Factsheet - VLT AutomationDrive FC 302 - Predictive/condition-based maintenance functions – for maximum availability of your application | Chinese (CN) | Taiwan | 28 Oct, 2022 | 1.5 MB | |
Case story | FORST Brewery (MEXICO) | Spanish | Spanish, Castilian | Multiple | 19 Jul, 2023 | 1.6 MB | |
Case story | FORST Brewery | English | English | Multiple | 19 Jul, 2023 | 1.6 MB | |
Case story | FORST Brewery | Italian | Italian | Multiple | 19 Jul, 2023 | 1.6 MB | |
Case story | FORST Brewery | Spanish | Spanish, Castilian | Multiple | 19 Jul, 2023 | 1.6 MB | |
Case story | Fugløyhav | Chinese | Chinese (CN) | Multiple | 22 Mar, 2023 | 3.5 MB | |
Case story | Fugløyhav | Danish | Danish | Multiple | 22 Mar, 2023 | 2.9 MB | |
Case story | Fugløyhav | English | English | Multiple | 22 Mar, 2023 | 2.5 MB | |
Application guide | Fuses and Circuit Breakers | English | Multiple | 17 Nov, 2010 | 295.6 KB | |
Case story | Gostol Gopan | English | English | Multiple | 15 Mar, 2023 | 2.3 MB | |
Case story | Gostol Gopan | French | French | Multiple | 15 Mar, 2023 | 2.4 MB | |
Case story | Gostol Gopan | Turkish | Turkish | Multiple | 15 Mar, 2023 | 2.3 MB | |
Case story | HAK Processed Fruit | Dutch | Dutch, Flemish | Multiple | 19 Jul, 2023 | 4.0 MB | |
Case story | Hans Weber JKC - Full case | Chinese | Chinese (CN) | Multiple | 31 May, 2023 | 1.6 MB | |
Case story | Hans Weber JKC - Full case | English | English | Multiple | 12 Apr, 2023 | 1.5 MB | |
Case story | Hans Weber JKC - Full case | German | German | Multiple | 12 Apr, 2023 | 1.6 MB | |
Case story | Hans Weber JKC - Full case | Turkish | Turkish | Multiple | 12 Apr, 2023 | 1.5 MB | |
Case story | Hans Weber JKC - Mobile case | English | English | Multiple | 21 Mar, 2022 | 781.7 KB | |
Case story | Hans Weber JKC - Short case | English | English | Multiple | 18 Jan, 2022 | 638.2 KB | |
Case story | Heineken (2016) | Dutch | Dutch, Flemish | Multiple | 15 Mar, 2023 | 3.0 MB | |
Case story | Heineken (2016) | English | English | Multiple | 15 Mar, 2023 | 3.1 MB | |
Case story | Heineken CBM - Full case | Chinese | Chinese (CN) | China | 04 May, 2022 | 3.0 MB | |
Case story | Heineken CBM - Full case | English | English | Multiple | 17 Mar, 2022 | 2.9 MB | |
Case story | Heineken CBM - Full case | French | French | Multiple | 05 May, 2022 | 2.9 MB | |
Case story | Heineken CBM - Full case | German | German | Multiple | 05 May, 2022 | 3.0 MB | |
Case story | Heineken CBM - Mobile case | English | English | Multiple | 09 Nov, 2021 | 1.1 MB | |
Case story | Heineken CBM - Short case | English | English | Multiple | 17 Mar, 2022 | 1.3 MB | |
Case story | Heineken Zagorka Brewery | English | English | Multiple | 16 Mar, 2023 | 3.1 MB | |
Case story | Hjoerring Multi Biofuel | Danish | Danish | Multiple | 03 May, 2023 | 4.3 MB | |
Case story | Hjoerring Multi Biofuel | Dutch | Dutch, Flemish | Multiple | 03 May, 2023 | 4.3 MB | |
Case story | Hjoerring Multi Biofuel | English | English | Multiple | 03 May, 2023 | 4.3 MB | |
Case story | Hjoerring Multi Biofuel | French | French | Multiple | 03 May, 2023 | 4.3 MB | |
Case story | Hjoerring Multi Biofuel | Turkish | Turkish | Multiple | 03 May, 2023 | 4.3 MB | |
Case story | Horsens Heating Plant | Danish | Danish | Multiple | 09 Jun, 2023 | 2.3 MB | |
Case story | Horsens Heating Plant | English | English | Multiple | 09 Jun, 2023 | 2.3 MB | |
Case story | Hymech Bottle Labeller | English | English | Multiple | 19 Jul, 2023 | 1.1 MB | |
Case story | IMC Stereoscopic Warehouse | Chinese | Chinese (CN) | Multiple | 05 Feb, 2023 | 1.9 MB | |
Fact sheet | IP 66/Type 4x enclosed VLT® drives up to 90 kW | English | Multiple | 11 Aug, 2023 | 888.9 KB | |
Fact sheet | IP 66/Type 4x enclosed VLT® drives up to 90 kW | Finnish | Multiple | 11 Aug, 2023 | 923.3 KB | |
Case story | Italcementi | English | English | Multiple | 16 Mar, 2023 | 7.4 MB | |
Case story | Italcementi | US English | English | United States | 16 Mar, 2023 | 7.4 MB | |
Case story | JHV Sugars | English | English | Multiple | 19 Jul, 2023 | 928.2 KB | |
Case story | Kamenitza Brewery BU | Czech | Czech | Multiple | 19 Jul, 2023 | 820.7 KB | |
Case story | Kamenitza Brewery BU | English | English | Multiple | 19 Jul, 2023 | 762.5 KB | |
Case story | Kolomela Mine SA | Chinese | Chinese (CN) | Multiple | 16 Mar, 2023 | 4.4 MB | |
Case story | Kolomela Mine SA | English | English | Multiple | 16 Mar, 2023 | 4.2 MB | |
Case story | Kolomela Mine SA | Polish | Polish | Multiple | 16 Mar, 2023 | 4.3 MB | |
Case story | Kolomela Mine SA | US English | English | United States | 16 Mar, 2023 | 4.1 MB | |
Case story | Lithium battery enterprise - Mobile case | Chinese | Chinese (CN) | Multiple | 18 Jan, 2023 | 2.7 MB | |
Case story | Lithium battery enterprise - Short case | Chinese | Chinese (CN) | Multiple | 18 Jan, 2023 | 11.8 MB | |
Case story | Luxeapers | English | English | Multiple | 03 May, 2023 | 2.6 MB | |
Case story | Luxeapers | Spanish | Spanish, Castilian | Multiple | 03 May, 2023 | 2.6 MB | |
Case story | Maersk Shore supply | Chinese | Chinese (CN) | Multiple | 22 Mar, 2023 | 12.0 MB | |
Case story | Maersk Shore supply | English | English | Multiple | 22 Mar, 2023 | 11.7 MB | |
Case story | Markus Kaffee | English | English | Multiple | 19 Jul, 2023 | 1.0 MB | |
Case story | MEC BioGas | Danish | Danish | Multiple | 22 Mar, 2023 | 6.4 MB | |
Case story | MEC BioGas | Dutch | Dutch, Flemish | Multiple | 22 Mar, 2023 | 6.3 MB | |
Case story | MEC BioGas | English | English | Multiple | 22 Mar, 2023 | 6.2 MB | |
Case story | MEC BioGas | Swedish | Swedish | Multiple | 22 Mar, 2023 | 6.4 MB | |
Case story | Metalika IMC Serbia | Chinese | Chinese (CN) | Multiple | 22 Mar, 2023 | 5.2 MB | |
Case story | Metalika IMC Serbia | Dutch | Dutch, Flemish | Multiple | 22 Mar, 2023 | 5.1 MB | |
Case story | Metalika IMC Serbia | English | English | Multiple | 22 Mar, 2023 | 5.0 MB | |
Case story | Mining Barge Serbia | English | English | Multiple | 20 Jul, 2023 | 1.0 MB | |
Case story | MV Island Performer Ulstein | Chinese | Chinese (CN) | Multiple | 16 Mar, 2023 | 3.3 MB | |
Case story | MV Island Performer Ulstein | English | English | Multiple | 16 Mar, 2023 | 3.1 MB | |
Case story | Nestle Waters | Chinese | Chinese (CN) | Multiple | 16 Mar, 2023 | 4.9 MB | |
Case story | Nestle Waters | English | English | Multiple | 16 Mar, 2023 | 4.7 MB | |
Case story | Nestle Waters | Italian | Italian | Multiple | 16 Mar, 2023 | 3.4 MB | |
Case story | Nestle Waters | Polish | Polish | Multiple | 16 Mar, 2023 | 4.7 MB | |
Case story | Novozymes Fermentation | English | English | Multiple | 17 Jul, 2023 | 307.8 KB | |
Case story | Palm Oil Refinery | English | English | Multiple | 19 Jul, 2023 | 2.0 MB | |
Case story | Palm Oil Refinery | Spanish | Spanish, Castilian | Multiple | 19 Jul, 2023 | 2.1 MB | |
Case story | PET Coke pipe conveyor | English | English | Multiple | 03 May, 2023 | 1.8 MB | |
Case story | Philips India | English | English | Multiple | 20 Jul, 2023 | 418.3 KB | |
Case story | Powder mixing NL | English | English | Multiple | 16 Mar, 2023 | 2.7 MB | |
Case story | Powder mixing NL | French | French | Multiple | 16 Mar, 2023 | 2.7 MB | |
Fact sheet | Power Limit function | English | English | Multiple | 28 Jul, 2023 | 993.8 KB | |
Fact sheet | Power Limit function | Russian | Russian | Multiple | 28 Jul, 2023 | 1.0 MB | |
Case story | Riunite | English | English | Multiple | 17 Mar, 2023 | 2.6 MB | |
Case story | Riunite | Italian | Italian | Multiple | 17 Mar, 2023 | 2.7 MB | |
Case story | Rolex Paper India | English | English | Multiple | 20 Jul, 2023 | 291.5 KB | |
Case story | Rothaus Brewery | Czech | Czech | Multiple | 19 Jul, 2023 | 3.2 MB | |
Case story | Rothaus Brewery | English | English | Multiple | 19 Jul, 2023 | 3.2 MB | |
Case story | Rothaus Brewery | Spanish | Spanish, Castilian | Multiple | 19 Jul, 2023 | 3.2 MB | |
Brochure | Safety and performance optimization of industrial cranes | English | Multiple | 23 Nov, 2021 | 18.6 MB | |
Brochure | Safety and performance optimization of industrial cranes | Russian | Central Asia Unit | 23 Nov, 2021 | 18.7 MB | |
Brochure | Safety and performance optimization of industrial cranes | Italian | Italy | 23 Nov, 2021 | 18.6 MB | |
Case story | Sagrex Lemay | Dutch | Dutch, Flemish | Multiple | 22 Mar, 2023 | 11.4 MB | |
Case story | Sagrex Lemay | English | English | Multiple | 22 Mar, 2023 | 11.3 MB | |
Case story | Sagrex Lemay | French | French | Multiple | 22 Mar, 2023 | 11.4 MB | |
Case story | Sibeg Bottling | English | English | Multiple | 19 Jul, 2023 | 1.5 MB | |
Application guide | Siemens S7 PLC and FC 300 Profibus | English | Multiple | 20 May, 2005 | 852.8 KB | |
Fact sheet | Software Enhancements | English | English | Multiple | 28 Jul, 2023 | 1.3 MB | |
Case story | Spinning Mills Bangladesh | English | English | Multiple | 20 Jul, 2023 | 786.0 KB | |
Case story | Stiegl Brewery | English | English | Multiple | 17 Mar, 2023 | 3.1 MB | |
White paper | SynchStarter solution | English | English | Multiple | 24 Aug, 2023 | 4.8 MB | |
Case story | Tavina | English | English | Multiple | 21 Mar, 2023 | 5.2 MB | |
Case story | Tavina | Italian | Italian | Multiple | 21 Mar, 2023 | 5.3 MB | |
Case story | TEX Services | English | English | Multiple | 03 May, 2023 | 2.4 MB | |
Case story | Trident Paper India |English | English | Multiple | 20 Jul, 2023 | 419.7 KB | |
Case story | Valser Mineral Water | English | English | Multiple | 19 Jul, 2023 | 2.1 MB | |
Case story | Van Asten | Dutch | Dutch, Flemish | Multiple | 22 Mar, 2023 | 19.9 MB | |
Case story | Van Asten | English | English | Multiple | 22 Mar, 2023 | 19.9 MB | |
Application guide | VLT drives with integrated CBM | English | Multiple | 15 May, 2022 | 1.2 MB | |
White paper | VLT drives with integrated CBM - Czech | Czech | Multiple | 23 Apr, 2024 | 13.3 MB | |
White paper | VLT drives with integrated CBM - English | English | Multiple | 13 May, 2022 | 13.3 MB | |
Application guide | VLT Integrated Motion Controller Appl G. | English | Multiple | 15 Dec, 2019 | 31.3 MB | |
Fact sheet | VLT® 12-pulse drive | English | Multiple | 19 Jul, 2023 | 1.5 MB | |
Design guide | VLT® Advanced Harmonic Filter AHF005-010 | German | Multiple | 15 Mar, 2022 | 6.3 MB | |
Design guide | VLT® Advanced Harmonic Filter AHF005-010 | Russian | Multiple | 15 Mar, 2022 | 6.5 MB | |
Design guide | VLT® Advanced Harmonic Filter AHF005-010 | English | Multiple | 15 Feb, 2022 | 6.2 MB | |
Design guide | VLT® Advanced Harmonic Filter AHF005-010 | Chinese (CN) | China | 15 Mar, 2022 | 6.5 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Dutch, Flemish | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Greek (modern) | Multiple | 29 Feb, 2024 | 5.2 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | German | Multiple | 29 Feb, 2024 | 5.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Slovenian | Multiple | 15 Feb, 2022 | 6.0 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Thai | Multiple | 15 Feb, 2022 | 6.3 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Ukrainian | Multiple | 15 Sep, 2021 | 28.8 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Turkish | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Swedish | Multiple | 15 Feb, 2022 | 6.0 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Chinese (CN) | China | 15 Feb, 2022 | 6.2 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Polish | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Portuguese | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Croatian | Multiple | 29 Feb, 2024 | 5.2 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Hungarian | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Slovak | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Russian | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Czech | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Romanian, Moldavian, Moldovan | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | French | Multiple | 29 Feb, 2024 | 5.2 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | English | Multiple | 15 Dec, 2020 | 28.7 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Chinese (CN) | Taiwan | 15 Feb, 2022 | 6.3 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Danish | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Bulgarian | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | English | United States | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Indonesian | Multiple | 15 Feb, 2022 | 6.0 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Italian | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Finnish | Multiple | 29 Feb, 2024 | 5.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Japanese | Multiple | 15 Feb, 2022 | 6.2 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Serbian (RS) | Multiple | 15 Feb, 2022 | 6.1 MB | |
Operating guide | VLT® AutomationDrive FC 300 0.25-75 kW | Korean | Multiple | 15 Feb, 2022 | 6.2 MB | |
Design guide | VLT® AutomationDrive FC 300 315–1200 kW | English | United States | 15 Nov, 2017 | 7.3 MB | |
Fact sheet | VLT® AutomationDrive FC 300 Ambient temperature and derating charts | English | Multiple | 07 Aug, 2023 | 460.4 KB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | English | Multiple | 07 Mar, 2023 | 68.7 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Chinese | Chinese (CN) | Multiple | 16 Mar, 2023 | 69.0 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Chinese Taiwan | Chinese (CN) | Taiwan | 16 Mar, 2023 | 69.1 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Czech | Czech | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Dutch | Dutch, Flemish | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | French | French | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | German | German | Multiple | 07 Mar, 2023 | 68.9 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Hungarian | Hungarian | Multiple | 16 Mar, 2023 | 68.6 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Italian | Italian | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Korean | Korean | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Polish | Polish | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Portuguese | Portuguese | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Russian | Russian | Multiple | 23 Jan, 2024 | 68.9 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | Spanish | Spanish, Castilian | Multiple | 16 Mar, 2023 | 68.8 MB | |
Brochure | VLT® AutomationDrive FC 300 series, VLT® Decentral Drive FCD 302 Selection Guide | US English | English | United States | 14 Jun, 2023 | 58.3 MB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet | Portuguese | Multiple | 07 Mar, 2023 | 482.5 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet | Romanian, Moldavian, Moldovan | Multiple | 07 Mar, 2023 | 916.6 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet | Chinese (CN) | Multiple | 07 Mar, 2023 | 442.6 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet | Italian | Multiple | 07 Mar, 2023 | 316.8 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet | English | Multiple | 07 Mar, 2023 | 462.3 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Fact Sheet - Chinese (Taiwan) | Chinese (CN) | Taiwan | 25 Mar, 2024 | 411.2 KB | |
Fact sheet | VLT® AutomationDrive FC 301/302 Factsheet | Spanish, Castilian | Multiple | 07 Mar, 2023 | 316.8 KB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Italian | Multiple | 15 May, 2018 | 10.8 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Korean | Multiple | 15 May, 2019 | 10.5 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Dutch, Flemish | Multiple | 15 May, 2019 | 10.7 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Portuguese | Multiple | 15 May, 2019 | 10.6 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Russian | Multiple | 15 May, 2019 | 10.7 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | German | Multiple | 15 May, 2018 | 10.6 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Spanish, Castilian | Multiple | 15 Nov, 2017 | 10.7 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | English | Multiple | 15 Nov, 2017 | 7.3 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | French | Multiple | 15 May, 2018 | 10.8 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Swedish | Multiple | 15 May, 2018 | 10.6 MB | |
Design guide | VLT® AutomationDrive FC 302 315–1200 kW | Chinese (CN) | China | 15 May, 2019 | 10.5 MB | |
Design guide | VLT® AutomationDrive FC 302 90-710kW | English | Multiple | 15 Sep, 2019 | 18.7 MB | |
Fact sheet | VLT® AutomationDrive FC 302 Active Front End | English | United States | 11 Aug, 2023 | 464.4 KB | |
Fact sheet | VLT® AutomationDrive FC 302 Active Front End | Spanish, Castilian | Multiple | 11 Aug, 2023 | 318.9 KB | |
Fact sheet | VLT® AutomationDrive FC 302 Active Front End | English | Multiple | 11 Aug, 2023 | 464.5 KB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | German | Multiple | 13 Mar, 2018 | 14.7 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | English | Multiple | 15 Jan, 2018 | 13.6 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | Spanish, Castilian | Multiple | 13 Mar, 2018 | 14.8 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | French | Multiple | 13 Mar, 2018 | 14.8 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | Italian | Multiple | 13 Mar, 2018 | 14.8 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | Portuguese | Multiple | 13 Mar, 2018 | 14.7 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | Russian | Multiple | 13 Mar, 2018 | 14.8 MB | |
Design guide | VLT® AutomationDrive FC 302, 90-710 kW | Chinese (CN) | Taiwan | 13 Mar, 2018 | 14.7 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | German | Multiple | 19 Feb, 2024 | 10.2 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Danish | Multiple | 18 Dec, 2013 | 6.7 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Chinese (CN) | China | 18 Dec, 2013 | 6.9 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Swedish | Multiple | 18 Dec, 2013 | 7.6 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Dutch, Flemish | Multiple | 18 Dec, 2013 | 7.5 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Russian | Multiple | 18 Dec, 2013 | 7.3 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | French | Multiple | 18 Dec, 2013 | 7.6 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Korean | Multiple | 18 Dec, 2013 | 7.0 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Italian | Multiple | 18 Dec, 2013 | 7.6 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | English | Multiple | 15 Oct, 2019 | 35.9 MB | |
Design guide | VLT® AutomationDrive FC301-302 0.25-75kW | Spanish, Castilian | Multiple | 18 Dec, 2013 | 7.6 MB | |
White paper | VLT® AutomationDrive for marine winch applications | English | Multiple | 24 Aug, 2023 | 5.0 MB | |
Design guide | VLT® Brake Resistor MCE 101 | German | Multiple | 09 Jul, 2014 | 8.5 MB | |
Design guide | VLT® Brake Resistor MCE 101 | English | Multiple | 08 May, 2014 | 8.5 MB | |
Operating guide | VLT® CANopen MCA 105 | German | Multiple | 22 Jun, 2015 | 3.4 MB | |
Operating guide | VLT® CANopen MCA 105 | English | Multiple | 22 May, 2015 | 3.4 MB | |
Application guide | VLT® DeviceNet & Control logix 5550 | English | Multiple | 20 May, 2005 | 3.5 MB | |
Fact sheet | VLT® DeviceNet Converter MCA 194 | English | Multiple | 09 Aug, 2023 | 1.2 MB | |
Fact sheet | VLT® DeviceNet MCA 104 | English | Multiple | 09 Aug, 2023 | 985.8 KB | |
Fact sheet | VLT® drive with enclosure size D - English | English | Multiple | 07 Feb, 2023 | 474.0 KB | |
Fact sheet | VLT® drive with enclosure size D - Portuguese | Portuguese | Multiple | 07 Feb, 2023 | 504.3 KB | |
Fact sheet | VLT® drive with enclosure size E - Danish | Danish | Multiple | 25 Jan, 2023 | 581.1 KB | |
Fact sheet | VLT® drive with enclosure size E - Dutch | Dutch, Flemish | Multiple | 25 Jan, 2023 | 561.4 KB | |
Fact sheet | VLT® drive with enclosure size E - English | English | Multiple | 24 Jan, 2023 | 551.8 KB | |
Fact sheet | VLT® drive with enclosure size E - French | French | Multiple | 25 Jan, 2023 | 594.2 KB | |
Fact sheet | VLT® drive with enclosure size E - German | German | Multiple | 25 Jan, 2023 | 618.4 KB | |
Fact sheet | VLT® drive with enclosure size E - Italian | Italian | Multiple | 25 Jan, 2023 | 582.7 KB | |
Fact sheet | VLT® drive with enclosure size E - US English | English | United States | 25 Jan, 2023 | 531.1 KB | |
Application guide | VLT® Drives Motor overload protection | English | Multiple | 19 Aug, 2008 | 212.6 KB | |
Fact sheet | VLT® EtherCAT MCA 124 | German | Multiple | 08 Aug, 2023 | 1.1 MB | |
Fact sheet | VLT® EtherCAT MCA 124 | English | Multiple | 08 Aug, 2023 | 1.1 MB | |
Design guide | VLT® FC Series Output Filter Design G. | English | Multiple | 22 Feb, 2011 | 4.8 MB | |
Design guide | VLT® FC-Seria filtros salida Guía Diseño | Spanish, Castilian | Multiple | 22 Feb, 2011 | 4.8 MB | |
Design guide | VLT® FC-Serie Ausgangsfilt. Projekthand. | German | Multiple | 22 Feb, 2011 | 5.1 MB | |
Design guide | VLT® FC-Serie Output Filter Design Guide | French | Multiple | 22 Feb, 2011 | 5.0 MB | |
Fact sheet | VLT® Modbus TCP MCA 122 | German | Multiple | 09 Aug, 2023 | 836.2 KB | |
Fact sheet | VLT® Modbus TCP MCA 122 | English | Multiple | 09 Aug, 2023 | 818.2 KB | |
Fact sheet | VLT® Parallel Drive Modules | English | Multiple | 11 Aug, 2023 | 446.0 KB | |
Fact sheet | VLT® Parallel Drive Modules | Spanish, Castilian | Multiple | 11 Aug, 2023 | 409.2 KB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | French | Multiple | 25 May, 2017 | 18.2 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | English | Multiple | 15 Aug, 2017 | 16.4 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | German | Multiple | 25 May, 2017 | 17.7 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | Spanish, Castilian | Multiple | 25 May, 2017 | 17.7 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | Portuguese | Multiple | 25 May, 2017 | 18.4 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | Italian | Multiple | 25 May, 2017 | 18.3 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | Chinese (CN) | China | 25 May, 2017 | 17.1 MB | |
Design guide | VLT® Parallel Drive Modules, 250–1200 kW | Russian | Multiple | 25 May, 2017 | 17.2 MB | |
Fact sheet | VLT® Parallel Drive Modulesa | Hungarian | Multiple | 11 Aug, 2023 | 794.3 KB | |
Fact sheet | VLT® POWERLINK MCA 123 | English | Multiple | 08 Aug, 2023 | 1.0 MB | |
Fact sheet | VLT® POWERLINK MCA 123 | German | Multiple | 08 Aug, 2023 | 1.1 MB | |
Fact sheet | VLT® PROFIBUS Converter MCA 113 | English | Multiple | 09 Aug, 2023 | 1.1 MB | |
Fact sheet | VLT® PROFIBUS Converter MCA 114 | English | Multiple | 09 Aug, 2023 | 1.2 MB | |
Fact sheet | VLT® Real-time Clock MCB 117 | Advanced data logging by time stamping | German | Multiple | 26 Apr, 2023 | 1.0 MB | |
Fact sheet | VLT® Safety Option MCB 150/151 and VLT® Sensorless Safety MCB 159 | Operate safely and reduce system cost | German | Multiple | 27 Apr, 2023 | 630.2 KB | |
Fact sheet | VLT® Safety Option MCB 150/151 and VLT® Sensorless Safety MCB 159 | Operate safely and reduce system cost | Danish | Multiple | 26 Apr, 2023 | 1.3 MB | |
Fact sheet | VLT® Safety Option MCB 150/151 and VLT® Sensorless Safety MCB 159 | Operate safely and reduce system cost | Dutch, Flemish | Multiple | 27 Apr, 2023 | 590.4 KB | |
Fact sheet | VLT® Safety Option MCB 150/151 and VLT® Sensorless Safety MCB 159 | Operate safely and reduce system cost | French | Multiple | 27 Apr, 2023 | 603.6 KB | |
Fact sheet | VLT® Safety Option MCB 150/151 and VLT® Sensorless Safety MCB 159 | Operate safely and reduce system cost | English | Multiple | 26 Apr, 2023 | 957.9 KB | |
Fact sheet | VLT® Safety Option MCB 152 | English | Multiple | 08 Aug, 2023 | 817.2 KB | |
Fact sheet | VLT® Safety Option MCB 152 | German | Multiple | 08 Aug, 2023 | 811.1 KB | |
Case story | Wheat Biorefinery | English | English | Multiple | 22 Mar, 2023 | 552.9 KB | |
Case story | Wieselburger Brewery (MEXICO) | English | English | Multiple | 19 Jul, 2023 | 1.9 MB | |
Case story | Wieselburger Brewery | English | English | Multiple | 19 Jul, 2023 | 1.9 MB | |
Case story | Wieselburger Brewery | Spanish | Spanish, Castilian | Multiple | 19 Jul, 2023 | 1.8 MB |
Drawings
Can't find the 3D model or drawing you're looking for? Sort and filter the following table by using the icons at the top of the columns.
Software
MyDrive® Suite provides all the software you need to select, integrate, program, and operate VLT® AutomationDrive FC 301 and FC 302, in one place.
Related applications
Conveyors, positioning and synchronizing, cranes, mixers, centrifuges and palletizing and packaging machinery.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives and gear motors for conveyors in food and beverage
Ensure maximum uptime and lowest possible cost of ownership with hygienic, variable-speed conveyor control. IPA-certified.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives for compressors in food and beverage
Compressor speed control provides constant pressure regulation as well as reducing your energy consumption, especially for part-load operation.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives for conveyors in mining
Flexibility to control the speed of long conveyors can help optimize the complete system, reduce bottlenecks and extend motor lifetime.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives for fans in food and beverage applications
Variable speed fan control reduces costs by trimming energy consumption, and improves comfort levels by avoiding noise-generating frequencies.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives for industrial crane and hoist movement
To optimize crane performance, Danfoss offers flexible control strategies combined with energy efficiency, operating within stringent safety requirements.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Drives for marine fans and ventilation
Variable frequency fan control saves energy and reduces noise in technical rooms and refrigeration systems throughout your vessel.
Troubleshooting
Case stories
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Wind tunnel achieves 99.5% uptime with Danfoss DrivePro®
Belgium: Thanks to Danfoss DrivePro® services, LuxFly has achieved 99,5% uptime in Europe’s largest vertical wind tunnel that is used for skydiving.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }DrivePro® Lifecycle Services secure maximum uptime for Rothes CoRDe
SCOTLAND: The Rothes CoRDe plant, a biomass-fired combined heat and power (CHP) plant, ensured maximum uptime thanks to several DrivePro® Lifecycle Services.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Site assessment secures maximum uptime for K+S
GERMANY: Thanks to DrivePro® Life Cycle Services, a K+S potash mine got more uptime and a quick retrofit resulting in a better bottom line.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Maximizing uptime for high-volume bottle filling
NORTH MACEDONIA: To meet new standards for uptime, flexibility, and energy efficiency, Pivara Skopje’s RGB line needed modernization. The ideal VSDs? VLT® FlexConcept®.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Brewing up real change at HEINEKEN
NETHERLANDS: HEINEKEN understands that to meet demand, its production line must always be up to the task – with all assets expected to deliver a consistently reliable and excellent performance. At Den Bosch brewery, the tough working environment posed several challenges. The solution was an upgrade using drives with integrated condition-based monitoring.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Why use intelligent drives with integrated motion control for wafer machines?
AUSTRIA: Motion control is traditionally synonymous with exact position, velocity, and acceleration control. Typically, such applications require complex servo solutions or an AC drive plus an additional motion control assembly and an encoder. With the Integrated Motion Controller (IMC) function, Danfoss offered Bühler Group an attractive alternative to servo motion control.